lc1d50ap7-schneider electric
lc1d50ap7-schneider electric
Review:

Your inquiry has been sent successfully

There was an error sending your inquiry.

Check stock

LC1D50AP7 Schneider

Contactor Tesys D - 3P(3 NA) - AC-3 - 440 V 50 A - 230 V AC 50/60 Hz coil
€89.00 (Excl. VAT) €107.69 (inc. VAT)
Tax included
How many units do you want to buy?
Send your query!
LC1D50AP7
SCHNEIDER ELECTRIC

New product
3 Available (stock updated to 2024-04-20)
24-48 hours
0.85 Kg
122.00 x 55.00 x 120.00 cm
International deliveries
Quantity:
Novaut is not an authorized distributor for SCHNEIDER ELECTRIC. This is a SURPLUS product. The original manufacturer's warranty does not apply.
 Calculate Shipping Cost
Free Shipping
to Spain via Correos
Estimated delivery: No estimated delivery specified day(s)
Location: Warehouse 11

Main

TeSys Range

TeSys D Product Name

Product type or component Connector

LC1D device short name

Motor Control Contactor Application

Resistive load

Employment category AC-1

AC-4

AC-3

Number of 3P poles

Power pole contact composition 3 NA

[Ue] Rated operating voltage Supply circuit, state 1 <= 690 V AC 25...400 Hz

Power supply circuit, state 1 < = 300 V DC

[Ie] Nominal operating current 50 to 60 °C) in < = 440 V AC AC-3 for power supply circuit

80 to 60 °C) in < = 440 V AC AC-1 for power supply circuit

Motor power in kW 15 kW in 220...230 V AC 50/60 Hz - cable type: AC-3)

22 kW in 380...400 V AC 50/60 Hz - cable type: AC-3)

30 kW in 500 V AC 50/60 Hz - cable type: AC-3)

33 kW in 660...690 V AC 50/60 Hz - cable type: AC-3)

25 kW in 415 V AC 50/60 Hz - cable type: AC-3)

30 kW in 440 V AC 50/60 Hz - cable type: AC-3)

11 kW in 400 V AC 50/60 Hz - cable type: AC-4)

Power HP motor (UL / CSA) 3 hp in 115 V AC 50/60 Hz for 1 motor phase

7.5 hp in 230/240 V AC 50/60 Hz for 1 motor phase

15 hp in 200/208 V AC 50/60 Hz for 3 motor phases

15 hp in 230/240 V AC 50/60 Hz for 3 motor phases

40 hp in 460/480 V AC 50/60 Hz for 3 motor phases

40 hp in 575/600 V AC 50/60 Hz for 3 motor phases

AC control circuit type at 50/60 Hz

[Uc] control circuit voltage 230 V AC 50/60 Hz

Composition of contacts

Auxiliary

1 NA + 1 NC

[Uimp] Resistance to voltage peaks 6 kV according to IEC 60947

Surge category III

[Ith] Conventional thermal current 10 A in <60 °C for signalling circuit

80 A in <60 °C for power supply circuit

Irms nominal connection power 140 A AC for signaling circuit according to IEC 60947-5-1

1

250 A DC for signalling circuit according to IEC 60947-5-1

900 A in 440 V for power supply circuit according to IEC 60947

Assigned cutting power 900 A in 440 V for power supply circuit according to IEC 60947

[Icw] Permissible time current 400 A in <40 °C - 10 s for supply circuit

810 A in <40 °C - 1 s for power supply circuit

84 A in <40 °C - 10 min for power supply circuit

208 A in <40 °C - 1 min for power supply circuit

100 A - 1 s for signaling circuit

120 A - 500 ms for signaling circuit

140 A - 100 ms for signaling circuit

Associated fuse 10 A gG for signaling circuit according to IEC 60947-5-1

100 A gG in < = 690 V type 1 coordination for power supply circuit

100 A gG in < = 690 V type 2 coordination for power supply circuit

Medium impedance 1.5 mOhm - Ith 80 A 50 Hz for power supply circuit

[Ui] Rated insulation voltage Supply circuit, state 1 600 V CSA certified

Power supply circuit, state 1 600 V UL certified

Signalling circuit, state 1 690 V according to IEC 60947-1

Signalling circuit, status 1 600 V CSA certificd

Signalling circuit, state 1 600 V UL certified

Power supply circuit, state 1 690 V according to IEC 60947-4-1

Electrical durability 1.45 Mciclos 50 A AC-3 en Ue <= 440 V

1.1 Mciclos 80 A AC-1 en Ue <= 440 V

Pole dissipated power 3.7 W AC-3

9.6 W AC-1

Front cover With

Mounting Bracket Plate

Rail

CFS Standards C22.2 No 14

IN 60947-4-1

IN 60947-5-1

IEC 60947-4-1

IEC 60947-5-1

UL 508

GL Product Certifications

BV

GOST

CCC

CSA

UL

RINA

LROS (Lloyds Register of Shipping)

DNV

Type of connection Control circuit, state 1 Terminals screw 2 cable(s) 1... 2.5 mm²Flexible with

Control circuit, state 1 Terminals screw 1 cable(s) 1... 4 mm²Flexible without cable limb

Control circuit, state 1 Terminals screw 2 cable(s) 1... 4 mm²Flexible without cable limb

Control circuit, state 1 Terminals screw 1 cable(s) 1... 4 mm²Flexible with

Control circuit, state 1 Terminals screw 1 cable(s) 1... 4 mm²solid without cable limb

Control circuit, state 1 Terminals screw 2 cable(s) 1... 4 mm²solid without cable limb

Power circuit, state 1 screw connection 1 cable(s) 1... 35 mm²Flexible without limb

cable

Power circuit, state 1 screw connection 2 cable(s) 1... 25 mm²Flexible without limb

cable

Power circuit, state 1 screw connection 1 cable(s) 1... 35 mm²Flexible with

Power circuit, state 1 screw connection 2 cable(s) 1... 25 mm²Flexible with

Power circuit, state 1 screw connection 1 cable(s) 1... 35 mm²solid without limb of

cable

Power circuit, state 1 screw connection 2 cable(s) 1... 25 mm²solid without limb of

cable

Tightening torque Control circuit, state 1 1.7 N.m - in Screw terminals - with flat screwdriver Ø 6

Control circuit, state 1 1.7 N.m - in screw terminals - with screwdriver PHILIPS nº 2

Power circuit, state 1 8 N.m - in EverLink BTR screw connectors - 25...

35 mm² hexagonal 4 mm

Power circuit, state 1 5 N.m - in EverLink BTR screw connectors - 1... 25 mm²

hexagonal 4 mm

Maneuver duration 4...19 ms opening

12...26 ms closing

Safety reliability level B10d = 1369863 contactor cycles with nominal load according to EN/ISO 13849-1

B10d = 20000000 contactor cycles with mechanical load according to EN/ISO 13849-1

Mechanical durability 6 Mciclos

2

Operating range 3600 cyc/h in <60 °C

Complementary

Coil feature Without antiparasitic filter as standard

Call consumption in VA 140 VA 60 Hz 0.75 20 °C)

160 VA 50 Hz 0.75 20 °C)

Maintenance consumption in VA 13 VA 60 Hz 0.3 20 °C)

15 VA 50 Hz 0.3 20 °C)

Heat dissipation 4... 5 W at 50/60 Hz

Type of auxiliary contacts mechanically joined type 1 NA + 1 NC according to IEC 60947-5-1

mirror contact type 1 NC according to IEC 60947-4-1

Signaling circuit frequency 25...400 Hz

Minimum switching current 5 mA for signalling circuit

Minimum switching voltage 17 V for signalling circuit

Non-overlap time 1.5 ms in deexcitation between NA and NC contact

1.5 ms in excitation between NA and NC contact

Insulation resistance > 10 MOhm for signaling circuit

M2 contact compatibility

LC1D Compatibility Code

Motor power range 7... 11 kW in 200... 240 V 3 phases

15... 25 kW in 380... 440 V 3 phases

15... 25 kW in 200... 240 V 3 phases

30... 50 kW in 380... 440 V 3 phases

30... 50 kW in 480... 500 V 3 phases

Type of motor starter Direct contactor

Contactor coil voltage 230 V AC Standard

Environment

Ip20 front IP protection level according to IEC 60529

TH protection treatment according to IEC 60068-2-30

Degree of contamination 3

Ambient temperature of

storage

-60... 80 °C

Maximum operating altitude 3000 m without declassification

Fire resistance 850 °C according to IEC 60695-2-1

Flame resistance V1 according to UL 94

Mechanical resistance Vibrations open contactor, state 1 2 Gn, 5...300 Hz

Vibrations closed connector, state 1 4 Gn, 5...300 Hz

Impacts closed connector, state 1 15 Gn for 11 ms

Open contactor impacts, state 1 10 Gn for 11 ms

Height 122 mm

Width 55 mm

Depth 120 mm

Product weight 0.855 kg

Packaging units

Package Drive Type 1 PCE

Number of units in package 1 1

Package weight 1 0.948 kg

Package 1 Height 0,620 dm

Package 1 width 1,370 dm

Package 1 Length 1,520 dm

Package Drive Type 2 S02

Number of units in package 2 10

Package weight 2 9.9 kg

3

Package 2 Height 15 cm

Package width 2 30 cm

Package length 2 40 cm

Package Drive Type 3 P06

Number of units in package 3 160

Package 3 Weight 165.06 kg

Package 3 Height 77 cm

Package width 3 80 cm

Package 3 Length 60 cm

Sustainability of the offer

REACh compliant without SVHC Yes

Compliant EU RoHS Directive

EU RoHS Statement

No toxic heavy metals Yes

Mercury-free Yes

Information on exemptions from

RoHS

Yes

RoHS Regulations China RoHS Declaration China

RoHS China Proactive Statement (Outside the Legal Scope of RoHS China)

WEEE On the European Union market, the product must be disposed of according to a

specific waste collection and never end up in a dumpster.

No PVC Yes

Logistics Information

Country of Origin EN

Contractual guarantee

Warranty period 18 months

4

LC1D50AP7

Specific references

New product

No customer reviews for the moment.

Up
Menu
Close