In conformance with EMC Directive 2014/30/EU and Low Voltage Directive 2014/35/EU EN 60601-1: 2006 + A11: 2011 + A1: 2013 + A12: 2014 & EN 60601-1-2: 2015
Emission
EN/BS EN 55011 / EN/BS EN 55032,FCC Title 47:Class B
Harmonic Current Emissions
IEC61000-3-2: Meet Class D limit
Voltage Fluctuation and Flicker
IEC61000-3-3
Dynamic Response (Overshoot and Undershoot O/P Voltage)
± 5% @ with 50-100% load change
Vibration (Operating)
5-500Hz, 2Grms, 15 minute for each three axis
Shock Test (Non-Operating)
50G, 11ms, 3 shocks for each direction
Over Temperature
Latch Mode for Main output
Short Circuit
Hiccup Mode for Main output and Standby (Non-Latching, Auto-Recovery)
Power De-rating
Linear power derate from 100% load at 50°C, to 50% load at 70°C
Operating Altitude
Up to 5,000 meters (up to 16,400 feet or 106-54kPa)