MEB-500A24F AA
Fiche technique
- Output Current
- 21A
- Output Voltage
- 24V
- Output Power
- 504W
- Nominal Input Voltage
- 100-240Vac
- Input Voltage Range
- 90-264Vac
- Nominal Input Frequency
- 50-60Hz
- Input Frequency Range
- 47-63Hz
- Input Current
- 5A typ.@ 120Vac , 2.6A typ. @ 230Vac
- Efficiency at 100% load
- 92% typ. @ 230Vac
- Inrush Current
- 40A typ. @ 230Vac, Cold start, @ 25°C
- Power Factor at 100% load
- 0.98 typ. @ 115Vac, 0.96 typ. @ 230Vac
- Case Chassis / Cover
- Aluminum
- Cooling System
- Built-in Fan
- Operating Temperature
- -20°C to +70°C
- Storage Temperature
- -30°C to +80°C
- Operating Humidity
- 20 to 90% RH (Non-Condensing)
- Expected Cap Life Time
- 3 years (115Vac, 100% load @ 50°C)
- Emission
- EN/BS EN 55011 & compliant with EN/BS EN 55032, FCC Title 47:Class B
- Harmonic Current Emissions
- Meet Class A limit
- Line Regulation
- 96mv max.
- Load Regulation
- 150mv max.
- Start-up Time
- 800ms max.
- Hold-up Time
- 16ms typ. @ 120Vac (100% load)
- Dynamic Response (Overshoot and Undershoot O/P Voltage)
- ±10% @50-100% load (Slew Rate: 0.1A/µS, 50% duty cycle @ 100Hz)
- Vibration (Operating)
- IEC60068-2-6, Sine Wave: 10Hz to [email protected]/s2(2G peak); 10min per cycle, 60min per axis for all X,Y,Z direction
- Over Temperature
- Protection mode: Latch OFF.
- Protection Against Shock
- Class I with PE connection
- Output Voltage Adjustment Range
- 21.6V~26.4V
- Start-up with Capacitive Loads
- 8,800µF Max
- Wire
- AWG 22-12
- Shock Test (Operating)
- IEC60068-2-27, Half Sine Wave: 10G for a duration of 11ms, 3shocks for each 3 directions
- Pollution Degree
- 2
- Material and Parts
- RoHS Directive 2011/65/EU & EU/2015/863 Compliant