PMT-48V350W2BRB
Ficha técnica
- Output Current
- 7.3A
- Output Voltage
- 48V
- Output Power
- 350.4W
- Nominal Input Voltage
- 100-120Vac, 200-240Vac (Selectable by Switch)
- Input Voltage Range
- 90-132Vac, 180-264Vac (Selectable by Switch)
- Nominal Input Frequency
- 50-60Hz
- Input Frequency Range
- 47-63Hz
- Input Current
- 6A typ. @ 115Vac, 3.4A typ. @ 230Vac
- Efficiency at 100% load
- 88% typ. @ 230Vac
- Inrush Current
- 60A typ. @ 230Vac (Cold Start)
- Case Chassis / Cover
- SGCC
- Cooling System
- Force Cooling
- Operating Temperature
- -40°C to +70°C
- Storage Temperature
- -40°C to +85°C
- Operating Humidity
- 20 to 90% (Non-Condensing)
- Vibration (Non-Operating)
- IEC 60068-2-6, Random: 5Hz to 500Hz (2.09G); 20 min per axis for all X, Y, Z direction
- Expected Cap Life Time
- 10 years (230Vac, 50% load @ 40°C)
- UKCA
- In conformance with Electromagnetic Compatibility Regulations 2016 and Electrical Equipment (Safety) Regulations 2016
- Line Regulation
- ± 0.5% typ. @ 100-132Vac, 180-264Vac (Selectable by Switch)
- Load Regulation
- ±0.5% typ. @ 100-132Vac, 180-264Vac (Selectable by Switch)
- Start-up Time
- 1500ms typ. @ 115Vac & 230Vac
- Hold-up Time
- 20ms typ. @ 115Vac & 230Vac
- Dynamic Response (Overshoot and Undershoot O/P Voltage)
- ± 10% @ 115 & 230Vac input, 10-100% load (Slew Rate: 2.5A/µS, 50% duty cycle @ 5Hz & 10KHz)
- Vibration (Operating)
- IEC 60068-2-6, Sine Wave: 20Hz to 500Hz (5G); 10min per cycle, 60min for each axis (X, Y,Z)
- Shock Test (Non-Operating)
- IEC 60068-2-27, Half Sine Wave: 50G for a duration of 11ms, 3 shocks for each 3 directions
- Overvoltage
- 52.8V-64.8V SELV Output, Latch Mode
- Overload / Overcurrent
- 110-175% of rated load current, Hiccup Mode, Non-Latching (Auto-Recovery)
- Over Temperature
- Latch Mode
- Short Circuit
- Hiccup Mode, Non-Latching (Auto-recovery when the fault is removed)
- Output Voltage Adjustment Range
- 43.2-52.8Vdc
- Start-up with Capacitive Loads
- 2,000µF Max
- Operating Altitude
- 0 to 5,000 Meters (0 to 16,400 ft)
- Safety Entry Low Voltage
- SELV
- Immunity
- EN/BS EN 55035, KN35, EN/BS EN 61000-6-2 & Compliance to EN/BS EN 61000-6-1
- DC Input Voltage Range
- 127-375Vdc
- Indicator
- Green LED (DC OK)
- Shock Test (Operating)
- IEC 60068-2-27, Half Sine Wave: 10G for a duration of 11ms, 3 shock for each 3 directions.
- Pollution Degree
- 2
- Rise Time
- 30ms typ. @ 115Vac & 230Vac
- Over Voltage Category
- II
Nuevo
No customer reviews for the moment.