Output Current
6A
Output Voltage
15V
Output Power
90W
Line Regulation
± 0.5%
Load Regulation
±4.5%
Start-up Time
3000ms
Hold-up Time
20ms @ 115Vac&230Vac
Dynamic Response (Overshoot and Undershoot O/P Voltage)
± 5% @ 50-100% load
Nominal Input Voltage
100-240Vac
Input Voltage Range
90-264Vac
Nominal Input Frequency
50-60Hz
Input Frequency Range
47-63Hz
Efficiency at 100% load
89.1% (typ.)
Case Chassis / Cover
PC
Operating Temperature
0°C to +40°C
Storage Temperature
-40°C to +85°C
Operating Humidity
10-95% RH (Non-Condensing)
Shock Test (Non-Operating)
50G, 11ms, 3 shocks for each direction
Vibration (Non-Operating)
5-500Hz, 2.09Grms, 20 minute for each three axis
Overvoltage
150%, Latch Mode
Overload / Overcurrent
130% of rated load current, Hiccup Mode, (Non-Latching, Auto-Recovery)
Over Temperature
Hiccup Mode, (Non-Latching, Auto-Recovery)
Short Circuit
Hiccup Mode, (Non-Latching, Auto-Recovery)
MTBF
1 Million based on Telecordia SR-332
Electrical Safety
IEC 60950-1 (Ed.2,2005), IEC 62368-1, GB 4943.1-2011, GB 9254-2008, GB 17625.1-2003
UKCA
In conformance with Electrical Equipment (Safety) Regulations 2016, and Electromagnetic Compatibility Regulations 2016, Medical Devices Regulations 2002(UK MDR 2002)
ITE Safety
IEC 60950-1, IEC 62368-1, GB 4943.1, GB 9254, GB 17625.1
Emission
EN/BS EN 55011,EN/BS EN 55032, Compliance to FCC Title 47:Class B
Harmonic Current Emissions
IEC61000-3-2 Meet Class A limit
Leakage Current
0.1mA @ 264Vac NC1), 0.3mA @ 264Vac SFC2
Voltage Fluctuation and Flicker
EN61000-3-3
Voltage Dips
IEC61000-4-11
Inrush Current
50A @ 115Vac, 100A @ 230Vac (typ.)
Input Terminal
C14 socket
Output Terminal
4pin Din / Barrel type / Tuning fork type
ESD Immunity
IEC61000-4-2
Radiated Immunity
IEC61000-4-3
EFT
IEC61000-4-4
Surge
IEC61000-4-5
Conducted Immunity
IEC61000-4-6
Magnetic Field
IEC61000-4-8