PMT-D2V75W2CA
Ficha técnica
- Output Current
- 5A,2.1A
- Output Voltage
- 5V,24V
- Output Power
- 75.4W
- Nominal Input Voltage
- 100-240Vac
- Input Voltage Range
- 90-264Vac
- Nominal Input Frequency
- 50-60Hz
- Input Frequency Range
- 47-63Hz
- Input Current
- 1.4A typ. @ 115Vac, 0.85A typ. @ 230Vac
- Efficiency at 100% load
- 85% typ. @ 230Vac
- Inrush Current
- 55A typ. @ 230Vac
- Case Chassis / Cover
- Aluminium / SGCC
- Cooling System
- Convection
- Input Terminal
- M3.5 x 7 Pins (Rated 300V/20A)
- Operating Temperature
- -30°C to +70°C (-40°C Cold Start)
- Storage Temperature
- -40°C to +85°C
- Operating Humidity
- 20 to 90% RH (Non-Condensing)
- Vibration (Non-Operating)
- IEC 60068-2-6, Random: 5Hz to 500Hz (2.09G); 20 min per axis for all X, Y, Z direction
- Expected Cap Life Time
- 10 years (230Vac, 50% load @ 40°C)
- CE
- In conformance with EMC Directive 2014/30/EU and Low Voltage Directive 2014/35/EU
- UKCA
- In conformance with Electromagnetic Compatibility Regulations 2016 and Electrical Equipment (Safety) Regulations 2016
- Harmonic Current Emissions
- IEC/EN/BS EN 61000-3-2, Class A
- Line Regulation
- V1 & V2: ±0.5% typ. (@ 115Vac & 230Vac input)
- Load Regulation
- V1: ±1.5% typ. V2: ±0.5% typ. (@ 115Vac & 230Vac input)
- Start-up Time
- 500ms typ. @ 115Vac & 230Vac
- Hold-up Time
- 10ms typ. @ 115Vac, 50ms typ. @ 230Vac
- Dynamic Response (Overshoot and Undershoot O/P Voltage)
- ± 10% @ 230Vac input, 10-100% load (Slew Rate: 2.5A/µS, 50% duty cycle @ 5Hz & 10KHz)
- Vibration (Operating)
- IEC 60068-2-6, Sine Wave: 20Hz to 500Hz (5G); 10min per cycle, 60min for each axis (X, Y,Z)
- Shock Test (Non-Operating)
- IEC 60068-2-27, Half Sine Wave: 50G for a duration of 11ms, 3 shocks for each 3 directions
- Protection Against Shock
- Class I with PE connection
- Output Voltage Adjustment Range
- V1: Fixed; V2: 21.6 26.4V
- Start-up with Capacitive Loads
- V1 & V2: 8000uF Max
- Operating Altitude
- 0 to 5,000 Meters (0 to 16,400 ft)
- Safety Entry Low Voltage
- SELV
- Indicator
- Green LED (DC OK)
- Shock Test (Operating)
- IEC 60068-2-27, Half Sine Wave: 10G for a duration of 11ms, 3 shock for each 3 directions.
- Pollution Degree
- 3
- Rise Time
- 30ms typ. @ 115Vac & 230Vac
- Over Voltage Category
- II (Compliance to EN 62477-1 OVC III with 2000 meters altitude)
Nuevo