PMT-12V50W2BAB
Ficha técnica
- Output Current
- 4.2A
- Output Voltage
- 12V
- Output Power
- 50.4W
- Start-up Time
- 1,000ms typ. @ 115Vac, 500ms typ. @ 230Vac (100% load)
- Hold-up Time
- 15ms typ. @ 115Vac, 70ms typ. @ 230Vac
- Dynamic Response (Overshoot and Undershoot O/P Voltage)
- ± 10% @ 115 & 230Vac input, 10-100% load (Slew Rate: 2.5A/µS, 50% duty cycle @ 5Hz & 10KHz)
- Nominal Input Voltage
- 100-240Vac
- Input Voltage Range
- 90-264Vac
- Nominal Input Frequency
- 50-60Hz
- Input Frequency Range
- 47-63Hz
- Input Current
- 0.95A typ. @ 115Vac, 0.55A typ. @ 230Vac
- Efficiency at 100% load
- 85.0% typ. @ 230Vac
- Case Chassis / Cover
- Aluminium / SGCC
- Operating Temperature
- -30°C to +70°C (-40°C Cold Start)
- Storage Temperature
- -40°C to +85°C
- Operating Humidity
- 20 to 90% RH (Non-Condensing)
- Shock Test (Non-Operating)
- IEC 60068-2-27, Half Sine Wave: 50G for a duration of 11ms, 3 shocks for each 3 directions
- Vibration (Non-Operating)
- IEC 60068-2-6, Random: 5Hz to 500Hz (2.09G); 20 min per axis for all X, Y, Z direction
- Operating Altitude
- 0 to 5,000 Meters (16,400 ft.)
- Overvoltage
- 13.2V-17.4V SELV Output, Latch Mode
- Overload / Overcurrent
- 110-175% of rated load current, Hiccup Mode, Non-Latching (Auto-Recovery)
- Over Temperature
- Latch Mode
- Short Circuit
- Hiccup Mode, Non-Latching (Auto-Recovery when the fault is removed)
- Protection Against Shock
- Class I with PE*4 connection
- CE
- In conformance with EMC Directive 2014/30/EU and Low Voltage Directive 2014/35/EU
- UKCA
- In conformance with Electromagnetic Compatibility Regulations 2016 and Electrical Equipment (Safety) Regulations 2016
- Harmonic Current Emissions
- IEC/EN/BS EN 61000-3-2, Class A
- Rise Time
- 30ms typ. @ 115Vac & 230Vac
- Cooling System
- Convection
- Expected Cap Life Time
- 10 years (230Vac, 50% load @ 40°C)
- Voltage Fluctuation and Flicker
- IEC 61000-4-11
- Inrush Current
- 45A typ. @ 230Vac (Cold Start)
- Indicator
- Green LED (DC OK)
- Output Voltage Adjustment Range
- 10.8-13.2Vdc
- Start-up with Capacitive Loads
- 8,000µF Max
- Power Dissipation
- 0% load: 0.2W typ. @ 230Vac
- Vibration (Operating)
- IEC 60068-2-6, Sine Wave: 20Hz to 500Hz (5G); 10min per cycle, 60min for each axis (X, Y,Z)
- Shock Test (Operating)
- IEC 60068-2-27, Half Sine Wave: 10G for a duration of 11ms, 3 shock for each 3 directions.
- Pollution Degree
- 3
- Safety Entry Low Voltage
- SELV
- Over Voltage Category
- III (Compliance to EN 61558, EN 62477-1 with 2000 meters altitude)
Nuevo