MDS-090AAS24 BA
Ficha técnica
- Output Current
- 3.75A
- Output Voltage
- 24V
- Output Power
- 90W
- Line Regulation
- ± 0.5%
- Load Regulation
- ± 4.5%
- Start-up Time
- 3000ms
- Hold-up Time
- 20ms @ 115Vac&230Vac
- Dynamic Response (Overshoot and Undershoot O/P Voltage)
- ± 5% @ 50-100% load
- Nominal Input Voltage
- 100-240Vac
- Input Voltage Range
- 90-264Vac
- Nominal Input Frequency
- 50-60Hz
- Input Frequency Range
- 47-63Hz
- Efficiency at 100% load
- 90.3%
- Case Chassis / Cover
- PC
- Operating Temperature
- 0°C to +40°C
- Storage Temperature
- -40°C to +85°C
- Operating Humidity
- 10-95% RH (Non-Condensing)
- Shock Test (Non-Operating)
- 50G, 11ms, 3 shocks for each direction
- Vibration (Non-Operating)
- 5-500Hz, 2.09Grms, 20 minute for each three axis
- Operating Altitude
- 3,000 meters (9842.52 feet)
- Overvoltage
- 150%, Latch Mode
- Overload / Overcurrent
- 130% of rated load current, Hiccup Mode, (Non-Latching, Auto-Recovery)
- Over Temperature
- Hiccup Mode, (Non-Latching, Auto-Recovery)
- Short Circuit
- Hiccup Mode, (Non-Latching, Auto-Recovery)
- Protection Against Shock
- Class II with functional earth
- MTBF
- 1 Million based on Telecordia SR-332
- Electrical Safety
- IEC60950-1 (Ed.2,2005), IEC62368-1, GB4943.1-2011, GB9254-2008, GB17625.1-2003
- CE
- In conformance with EN 60601-1 & EN 60601-1-2
- UKCA
- Medical Devices Regulations 2002 (UK MDR 2002)
- ITE Safety
- IEC 60950-1, IEC 62368-1, GB 4943.1, GB 9254, GB 17625.1
- Emission
- EN/BS EN 55011, EN/BS EN 55032, FCC Title 47:Class B
- Harmonic Current Emissions
- IEC61000-3-2 Meet Class A limit
- Leakage Current
- 0.1mA @ 264Vac NC1), 0.3mA @ 264Vac SFC
- Voltage Fluctuation and Flicker
- EN61000-3-3
- Voltage Dips
- IEC61000-4-11
- Ripple and Noise
- 94.4mV pk-pk @ Full load
- Inrush Current
- 50A @ 115Vac, 100A @ 230Vac (typ.)
- Input Terminal
- C14 socket
- Output Terminal
- 4pin Din / Barrel type / Tuning fork type
- ESD Immunity
- IEC61000-4-2
- Radiated Immunity
- IEC61000-4-3
- EFT
- IEC61000-4-4
- Surge
- IEC61000-4-5
- Conducted Immunity
- IEC61000-4-6
- Magnetic Field
- IEC61000-4-8
Nuevo