DRL-15V240W1EN
Ficha técnica
- Output Current
- 16A
- Output Voltage
- 15V
- Output Voltage Range
- 13.5-16.5Vdc
- Output Power
- 240W
- Nominal Input Voltage
- 100-240Vac
- Input Voltage Range
- 90-264Vac
- Nominal Input Frequency
- 50-60Hz
- Input Frequency Range
- 47-63Hz
- Input Current
- 2.5A typ. @ 115Vac, 1.3A typ. @ 230Vac
- Efficiency at 100% load
- 87.0% typ. @ 230Vac
- Inrush Current
- 40A typ. @ 230Vac
- Case Chassis / Cover
- Aluminum / SGCC
- Cooling System
- Convection
- Input Terminal
- 3 Pins (Rated 300V/30A)
- Output Terminal
- 4 Pins (Rated 300V/20A)
- Operating Temperature
- -40°C to +70°C
- Storage Temperature
- -40°C to +85°C
- Operating Humidity
- 20 to 95% RH (Non-Condensing)
- Vibration (Non-Operating)
- IEC 60068-2-6, Random: 5Hz to 500Hz (2.09G); 20 min per axis for all X, Y, Z direction
- Expected Cap Life Time
- 10 years (230Vac, 50% load @ 40°C)
- CE
- In conformance with EMC Directive 2014/30/EU and Low Voltage Directive 2014/35/EU
- UKCA
- In conformance with Electrical Equipment (Safety) Regulations 2016 and Electromagnetic Compatibility Regulations 2016
- Harmonic Current Emissions
- IEC/EN/BS EN 61000-3-2, Class A
- Voltage Fluctuation and Flicker
- IEC/EN/BS EN 61000-3-3
- ESD Immunity
- IEC 61000-4-2
- EFT
- IEC 61000-4-4
- Surge
- IEC 61000-4-5
- Magnetic Field
- IEC 61000-4-8
- Voltage Dips
- IEC 61000-4-11
- Line Regulation
- ± 0.5% @ 115Vac & 230Vac
- Load Regulation
- ± 1.0%
- Start-up Time
- 500ms typ. @ 115Vac & 230Vac
- Dynamic Response (Overshoot and Undershoot O/P Voltage)
- ± 10% @ 115Vac & 230Vac input, 10-100% load (Slew Rate: 2.5A/µS, 50% duty cycle @ 5Hz & 10KHz)
- Vibration (Operating)
- IEC 60068-2-6, Sine Wave: 10Hz to 500Hz @ 19.6 m/s² (2G peak); 10 min per cycle, 60 min for X direction
- Shock Test (Non-Operating)
- IEC 60068-2-27, Half Sine Wave: 50G for duration of 11ms; 3 times per direction, 9 times in total
- Over Temperature
- Latch Mode
- Short Circuit
- Hiccup Mode, Non-Latching (Auto-recovery when the fault is removed)
- Protection Against Shock
- Class I with Primary Earth connection
- Output Voltage Adjustment Range
- 13.5-16.5 Vdc
- Start-up with Capacitive Loads
- 8,000µF Max
- Operating Altitude
- 0 to 5,000 Meters (16,400 ft.)
- Indicator
- Green LED (DC OK)
- Shock Test (Operating)
- IEC 60068-2-27, Half Sine Wave: 10G for duration of 11ms; 1 time in X axis
- Pollution Degree
- 2
- Component Power Supply for General Use
- EN/BS EN 61204-3
- Rise Time
- 30ms typ. @ 115Vac & 230Vac
- Over Voltage Category
- II (Compliance to EN 62477-1 OVC III with 2000 meters altitude)
- Internal Fuse
- T4 A / 250 V
- Mounting Rail
- Standard TS35 DIN Rail in accordance with EN 60715
- Radiated Immunity
- IEC 61000-4-3
- Conducted Immunity
- IEC 61000-4-6