USVI-080024FR1
Ficha técnica
- Output Current
- 3.33A
- Output Voltage
- 24V
- Output Power
- 80W
- Line Regulation
- ± 1%
- Load Regulation
- ± 3%
- Nominal Input Voltage
- 120-277Vac
- Input Voltage Range
- 108-305Vac
- Nominal Input Frequency
- 50-60 Hz
- Input Frequency Range
- 47-63Hz
- Input Current
- 0.76 typ.
- Efficiency at 100% load
- 90% typ. @ 230Vac
- Case Chassis / Cover
- Metal sheet
- Operating Temperature
- -40°C to +55°C
- Storage Temperature
- -40°C to +85°C
- Operating Humidity
- 10 to 90% RH (Non-Condensing)
- Overvoltage
- Auto-Recovery when the fault is removed
- Overload / Overcurrent
- Auto-Recovery when the fault is removed
- Over Temperature
- Auto-Recovery when the fault is removed
- Short Circuit
- Auto-Recovery when the fault is removed
- MTBF
- 850,000 hrs. @ta: +45°C (as per Telcordia SR-332 , total failure rate less than 10% )
- Emission
- Compliance to BS EN/EN 55015 & FCC Part 15 Class A
- Harmonic Current Emissions
- EN 61000-3-2 Class C (230Vac @ 100% load)
- Cooling System
- Convection
- Expected Cap Life Time
- 50,000 hrs. at lifetime case temperature
- Immunity
- Compliance to BS EN/EN 61547
- Voltage Fluctuation and Flicker
- IEC 61000-3-3
- Voltage Dips
- IEC 61000-4-11
- Radiated Immunity
- IEC 61000-4-3
- EFT
- IEC 61000-4-4
- Conducted Immunity
- IEC 61000-4-6
- Magnetic Field
- IEC 61000-4-8
- Storage Humidity
- 5 to 95% RH (Non-Condensing)
- Total Harmonic Distortion
- Meet IEC 61000-3-2 Class C
- Max Output Voltage
- 25.6Vdc
- Output Current Adjustment Range
- 0.1-2.5A
Nuevo
No customer reviews for the moment.