DRP-24V100W1NN
Fiche technique
- Output Current
- 3.8A
- Output Voltage
- 24V
- Output Power
- 91W
- Nominal Input Voltage
- 100-240Vac
- Input Voltage Range
- 85-264Vac
- Nominal Input Frequency
- 50-60Hz
- Input Frequency Range
- 47-63Hz
- Case Chassis / Cover
- Aluminium
- Cooling System
- Convection
- Input Terminal
- 3 Pins (Rated 600V/35A)
- Output Terminal
- 4 Pins (Rated 300V/28A)
- Operating Temperature
- -25°C to +80°C (Cold Start at -40°C)
- Storage Temperature
- -40°C to +85°C
- Operating Humidity
- 5 to 95% RH (Non-Condensing)
- Vibration (Non-Operating)
- IEC 60068-2-6, 10Hz to 500Hz @ 30m/S² (3G peak); 60 min per axis for all X, Y, Z direction
- Degree of Protection
- IP20
- Expected Cap Life Time
- 10 years (115Vac & 230Vac, 50% load @ 40°C)
- CE
- In conformance with EMC Directive 2014/30/EU and Low Voltage Directive 2014/35/EU
- UKCA
- In conformance with Electrical Equipment (Safety) Regulations 2016 No. 1011 and The Electromagnetic Compatibility Regulations 2016 No. 1091
- Harmonic Current Emissions
- IEC/EN/BS EN 61000-3-2, Class A
- Voltage Fluctuation and Flicker
- IEC/EN/BS EN 61000-3-3
- Dynamic Response (Overshoot and Undershoot O/P Voltage)
- ± 5% @ 85-264Vac input, 0-100% load (Slew Rate: 0.1A/µs, 50% duty cycle @ 5Hz to 1KHz)
- Shock Test (Non-Operating)
- IEC 60068-2-27, 30G (300m/S²) for a duration of 18ms, 1 times per direction, 2 times in total
- Short Circuit
- Hiccup Mode, Non-Latching (Auto-recovery when the fault is removed)
- Protection Against Shock
- Class I with Primary Earth connection
- Output Voltage Adjustment Range
- 22-24Vdc
- Start-up with Capacitive Loads
- 8,000µF Max
- Wire
- Input / Output: AWG 18-12
- Operating Altitude
- 0 to 2,500 Meters (8,200 ft)
- Safety Entry Low Voltage
- SELV (IEC 60950-1)
- Immunity
- Generic Standards: EN/BS EN 55024, EN/BS EN 61000-6-2
- DC Input Voltage Range
- 120-375Vdc
- Indicator
- Green LED (DC OK)
- Pollution Degree
- 2
- Component Power Supply for General Use
- EN/BS EN 61204-3
- Mounting Rail
- Standard TS35 DIN Rail in accordance with EN 60715
- Bump Test (Operating)
- IEC 60068-2-29, Half Sine Wave: 10G for a duration of 11ms, 1,000 times per direction, 6,000 times in total
- Electrical Equipments of Machines
- EN/BS EN 60204-1 (over voltage category III)
- Electrical Equipment for Use in Electrical Power Installations
- EN/BS EN 62477-1 / IEC 62103
Nouveau produit