DRM-24V960W1PN
Fiche technique
- Output Current
- 40A
- Output Voltage
- 24V
- Output Power
- 960W
- Line Regulation
- 10mV Max. (@ 85-264Vac input, 100% load)
- Start-up Time
- 800ms Max. @ 100Vac & 120Vac & 230Vac
- Hold-up Time
- 24ms Typ. @ 100Vac & 120Vac & 230Vac (100% load)
- Nominal Input Voltage
- 100-240Vac
- Input Voltage Range
- 85-264Vac
- Nominal Input Frequency
- 50-60Hz
- Input Frequency Range
- 47-63Hz
- Input Current
- 10.50A Typ. @ 100Vac, 8.60A Typ. @ 120Vac, 4.50A Typ. @ 230Vac
- Efficiency at 100% load
- 94.10% Typ. @ 100Vac, 94.71% Typ. @ 120Vac, 95.98% Typ. @ 230Vac
- Case Chassis / Cover
- Aluminium
- Operating Temperature
- -25°C to +70°C (Cold Start -40°C)
- Storage Temperature
- -40°C to +85°C
- Operating Humidity
- 5 to 95% RH (Non-Condensing)
- Shock Test (Non-Operating)
- IEC 60068-2-27, Half Sine Wave: 30G for a duration of 18ms; 3 times per direction, 6 times in total
- Vibration (Non-Operating)
- IEC 60068-2-6, Sine Wave: 10-500Hz; 3G peak; displacement of 0.35mm; 60 min per axis for all X, Y, Z directions
- Short Circuit
- Hiccup Mode, Non-Latching (Auto-Recovery when the fault is removed)
- Degree of Protection
- IP20
- Protection Against Shock
- Class I with Primary Earth connection
- CE
- In conformance with EMC Directive 2014/30/EU and Low Voltage Directive 2014/35/EU
- UKCA
- In conformance with Electrical Equipment (Safety) Regulations 2016 No. 1011 and The Electromagnetic Compatibility Regulations 2016 No. 1091
- Harmonic Current Emissions
- IEC/EN/BS EN 61000-3-2, Class A
- PARD
- 100mVpp Max.
- Power Factor at 100% load
- 0.99 Typ. @ 100Vac, 0.99 Typ. @ 120Vac, 0.96 Typ. @ 230Vac
- Cooling System
- Convection
- Immunity
- Generic Standards: EN/BS EN 55024, KN 35, EN/BS EN 61000-6-2
- Voltage Fluctuation and Flicker
- IEC/EN/BS EN 61000-3-3
- Inrush Current
- 11A Max. @ 100Vac, 13A Max. @ 120Vac, 20A Max. @ 230Vac
- Indicator
- Green LED (DC OK) and Red LED (Overload)
- Input Terminal
- 3 Pins (Rated 600V/35A)
- Output Terminal
- 4 Pins (Rated 300V/65A)
- Output Voltage Adjustment Range
- 24-28Vdc
- Start-up with Capacitive Loads
- 40,000µF Max.
- Signal Terminal
- 5 Pins (Rated 300V/10A)
- Mounting Rail
- Standard TS35 DIN Rail in accordance with EN 60715
- Pollution Degree
- 2
- Safety Entry Low Voltage
- SELV (IEC 60950-1)
- Component Power Supply for General Use
- EN/BS EN 61204-3
- Bump Test (Operating)
- IEC 60068-2-29, Half Sine Wave: 10G for a duration of 11ms, 1,000 times per direction, 6,000 times in total
- Electrical Equipments of Machines
- EN/BS EN 60204-1 (over voltage category III)
- Electrical Equipment for Use in Electrical Power Installations
- IEC/EN/BS EN 62477-1 / IEC 62103
- Power Boost Recovery Time
- 17 seconds Typ.
Nouveau produit