MDS-090BAS24 A
Ficha técnica
- Output Current
- 3.75A
- Output Voltage
- 24V
- Output Power
- 90W
- Line Regulation
- ±0.5% max.
- Load Regulation
- ±5% max.
- Start-up Time
- 3000ms
- Hold-up Time
- 6ms @ 115Vac&230Vac
- Dynamic Response (Overshoot and Undershoot O/P Voltage)
- ± 5% @ 50-100% load (Overshoot & Undershoot O/P Voltage)
- Nominal Input Voltage
- 100-240Vac
- Input Voltage Range
- 90-264Vac
- Nominal Input Frequency
- 50-60Hz
- Input Frequency Range
- 47-63Hz
- Input Current
- 2A @ 115Vac, 1A @ 230Vac
- Efficiency at 100% load
- 87.61% @ Full load
- Case Chassis / Cover
- PC
- Operating Temperature
- 0°C to +40°C
- Storage Temperature
- -40°C to +85°C
- Operating Humidity
- 10-95% RH (Non-Condensing)
- Shock Test (Non-Operating)
- 50G, 11ms, 3 shocks for each direction
- Vibration (Non-Operating)
- 5-500Hz, 2.09Grms, 20 minute for each three axis
- Operating Altitude
- 5,000 meters (16402 feet)
- Overvoltage
- 150%, Latch Mode (max.)
- Overload / Overcurrent
- 150% of rated load current (max.), Hiccup Mode, (Non-Latching, Auto-Recovery)
- Over Temperature
- Latch Mode or Auto-Recovery
- Short Circuit
- Hiccup Mode, (Non-Latching, Auto-Recovery)
- Degree of Protection
- IP22
- Protection Against Shock
- Class II
- MTBF
- 1 Million Hrs based on Telecordia SR-332
- Electrical Safety
- IEC 60950-1 (Ed.2,2005), IEC 62368-1, GB 4943.1-2011, GB 9254-2008, GB 17625.1-2003
- CE
- In conformance with EN 60601-1: 2006 + A11: 2011 + A1: 2013 + A12: 2014 & EN 60601-1-2: 2015
- Galvanic Isolation
- Input to Output 4000 Vac
- UKCA
- Medical Devices Regulations 2002 (UK MDR 2002)
- Emission
- EN/BS EN 55011, EN/BS EN 55032, Compliance to FCC Title 47:Class B
- Harmonic Current Emissions
- IEC61000-3-2 Meet Class A limit
Nuevo