Related products
RGC1A23D31KEM, RG single-phase solid state relays with integrated monitoring, RGC1A23D31KEM, RG solid state relays. M incorporate monitoring functions for rapid fault detection, in addition to its switching capacity (up to 30 ACA) in a narrow 17.8 mm box. Detectable faults: phase loss, pressure loss, open or short-circuited static relay, internal static relay failure and out-of-range power. They are also equipped with an alarm LED for visual indication of the presence of failure, as well as a transistor alarm output for remote signaling. RG solid state relays. M are available well with integrated heatsink, RGC. M or without heatsink, RGS.. M. Nominal output values are up to 660 WL, 65 ACA for RGC. M and 90 ACA for RGS.. M. RG relays.. M have to be powered at 24 VDC and the control voltage range is from 4 to 32 VDC. The data is based on 25ºC, unless otherwise specified., RGC1A23D31KEM, Typical applications for the RG.. M include plastics processing machines, packaging machines, semiconductor manufacturing, wood machinery and drying equipment. RG.. M is the right solution when it is crucial to avoid reworking the processed material due to a malfunction not detected in time. This feature applies in processes where it is necessary to immediately detect a deviation in temperature control or in temperature control processes that do not have an accurate response on temperature as often happens in applications with infrared heaters.