pmt-15v150w2ca-delta psu
pmt-15v150w2ca-delta psu
Review:

Your inquiry has been sent successfully

There was an error sending your inquiry.

Captcha validation failed.

Check stock

PMT-15V150W2CA DELTA

PMT-15V150W2CA DELTA
€41.60 (Excl. VAT) €50.34 (inc. VAT)
Tax included
Novaut is an authorized distributor for DELTA.
New product
New: Product directly from the manufacturer in original sealed packaging. Manufacturer warranty.

New surplus: Brand new equipment never used. Comes from excess materials or leftover from a project. May come in sealed original box, opened original box, or without original box, but equipment is completely new. NOVAUT warranty.

Refurbished: Products given a second life. High-quality products with worn components replaced, boards cleaned and treated. Fully tested to ensure proper functioning, remanufactured products. NOVAUT warranty.

Used: Products that have been used, not tested. NOVAUT warranty in case they do not function correctly.
/ Warranty: 3 years
5-7 days
International deliveries
How many units do you want to buy?
Send your query!
PMT-15V150W2CA
DELTA
Power Supplies DELTA DELTA
Quantity Price (Exc. VAT) Price (inc. VAT)
1 - 4 €41.60 €50.34
5 - 9 €40.54 €49.05
10 - 14 €39.00 €47.19
15 - 19 €37.08 €44.87
> 19 €34.66 €41.94
Novaut is an authorized distributor for DELTA.
New product
New: Product directly from the manufacturer in original sealed packaging. Manufacturer warranty.

New surplus: Brand new equipment never used. Comes from excess materials or leftover from a project. May come in sealed original box, opened original box, or without original box, but equipment is completely new. NOVAUT warranty.

Refurbished: Products given a second life. High-quality products with worn components replaced, boards cleaned and treated. Fully tested to ensure proper functioning, remanufactured products. NOVAUT warranty.

Used: Products that have been used, not tested. NOVAUT warranty in case they do not function correctly.
/ Warranty: 3 years
5-7 days
International deliveries
Quantity:
 Calculate Shipping Cost
Free Shipping
to Spain via Correos
Estimated delivery: No estimated delivery specified day(s)
Location: Warehouse 118

Related products

PMT-15V150W2CA DELTA
DELTA
PMT-15V150W2CA

Sheet

Output Current
0-10A
Output Voltage
15V
Output Power
150W
Line Regulation
± 0.5% typ. (@ 115Vac & 230Vac input)
Load Regulation
± 0.5% typ. (@ 115Vac & 230Vac input)
Start-up Time
500 ms typ. @ 115 Vac & 230 Vac
Hold-up Time
12 ms typ. @ 115 Vac & 55 ms typ. @230 Vac full load
Dynamic Response (Overshoot and Undershoot O/P Voltage)
± 10% @ 115 & 230 Vac input, 10-100% load (Slew Rate: 2.5 A/µS, 50% duty cycle @ 5 Hz & 10 KHz)
Nominal Input Voltage
100-240 Vac
Input Voltage Range
90-264 Vac
Nominal Input Frequency
50-60 Hz
Input Frequency Range
47-63Hz
Input Current
3 A typ. @ 115 Vac, 1.7 A typ. @ 230 Vac
Efficiency at 100% load
89% typ. @230 Vac
Case Chassis / Cover
Aluminum / SGCC
Operating Temperature
-30°C to +70°C ( -40°C Cold Start )
Storage Temperature
-40°C to +85°C
Operating Humidity
20 to 90% RH (Non-Condensing)
Shock Test (Non-Operating)
IEC 60068-2-27, Half Sine Wave: 50 G for a duration of 11 ms, 3 shocks for each 3 directions
Vibration (Non-Operating)
IEC 60068-2-6, Random: 5 Hz to 500 Hz (2.09 G); 20 min per axis for all X, Y, Z direction
Operating Altitude
0 to 5,000 Meters (0 to 16,400 ft)
Overvoltage
16.5 V - 21.0 V SELV Output, Latch Mode
Overload / Overcurrent
110-175% of rated load current, Hiccup Mode, Non-Latching (Auto-Recovery)
Over Temperature
Latch Mode
Short Circuit
Hiccup Mode, Non-Latching (Auto-Recovery when the fault is removed)
Protection Against Shock
Class I with Protechtion Earth connection
CE
In conformance with EMC Directive 2014/30/EU and Low Voltage Directive 2014/35/EU
UKCA
In conformance with Electromagnetic Compatibility Regulations 2016 and Electrical Equipment (Safety) Regulations 2016
Harmonic Current Emissions
IEC/EN/BS EN 61000-3-2 Class A
Rise Time
30 ms typ. @ 115 Vac & 230 Vac
Cooling System
Convection
Expected Cap Life Time
10 years (230Vac, 50% load @ 40°C)
Immunity
EN/ BS EN 55035, KN 35, EN/BS EN 61000-6-2 Compliance to EN/BS EN 55014-2, EN/BS EN 61000-6-1
Inrush Current
60 A typ. @ 230 Vac
Indicator
Green LED (DC OK)
Output Voltage Adjustment Range
13.5-16.5 Vdc
Start-up with Capacitive Loads
8,000 µF Max
Wire
AWG 18-12
Vibration (Operating)
IEC 60068-2-6, Sine Wave: 20 Hz to 500Hz (5 G); 10 min per cycle, 60min for each axis (X, Y,Z)
Shock Test (Operating)
IEC 60068-2-27, Half Sine Wave: 10 G for a duration of 11 ms, 3 shock for each 3 directions.
Pollution Degree
3
Safety Entry Low Voltage
SELV
Over Voltage Category
II (Compliance to EN 62477-1 OVC III with 2000 meters altitude)