PMR-5V320WCAA
Fiche technique
- Output Current
- 60A
- Output Voltage
- 5V
- Output Power
- 300W
- Nominal Input Voltage
- 100-240Vac
- Input Voltage Range
- 88-264Vac
- Nominal Input Frequency
- 50-60Hz
- Input Frequency Range
- 47-63Hz
- Efficiency at 100% load
- 81.0% typ. @ 115Vac, 84.0% typ. @ 230Vac
- Power Factor at 100% load
- 0.98 typ. @ 115Vac, 0.95 typ. @ 230Vac
- Case Chassis / Cover
- Aluminium
- Cooling System
- Forced Cooling, automatic fan speed control
- Operating Temperature
- -10°C to +70°C
- Storage Temperature
- -40°C to +85°C
- Operating Humidity
- 5 to 95% RH (Non-Condensing)
- Vibration (Non-Operating)
- IEC 60068-2-6, Random: 5Hz to 500Hz (2.09Grms); 20 min per axis for all X, Y, Z direction
- CE
- In conformance with EMC Directive 2004/108/EC and Low Voltage Directive 2006/95/EC
- Emission
- CISPR 22, EN 55022, FCC Title 47: Class B
- Harmonic Current Emissions
- IEC/EN 61000-3-2, Class A and Class D
- Voltage Fluctuation and Flicker
- IEC/EN 61000-3-3
- Line Regulation
- ± 0.5% typ. (@ 115Vac & 230Vac, 100% load)
- Load Regulation
- ± 1.0% typ. (@ 115Vac & 230Vac, 0-100% load)
- Hold-up Time
- 8ms typ. @ 115Vac & 230Vac
- Dynamic Response (Overshoot and Undershoot O/P Voltage)
- ± 1500mVpp @ 10-50% load and 50-100% load
- Shock Test (Non-Operating)
- IEC 60068-2-27, Half Sine: 50G for a duration of 11ms, 3 shocks for each 3 directions
- Overvoltage
- 5.75-7.50V, Latch Mode, Non-Latching
- Overload / Overcurrent
- 105-150%, Hiccup Mode, Non-Latching (Auto-Recovery)
- Over Temperature
- Hiccup Mode, Non-Latching (Auto-Recovery)
- Short Circuit
- Hiccup Mode, Non-Latching (Auto-Recovery)
- Protection Against Shock
- Class I with PE(Primary Earth) connection
- Output Voltage Adjustment Range
- 4.50-5.50Vdc
- Start-up with Capacitive Loads
- 8,000µF Max
- Immunity
- EN 55024
Nouveau produit