PMR-36V320W1AT
Fiche technique
- Output Current
- 8.9A
- Output Voltage
- 36V
- Output Power
- 320W
- Nominal Input Voltage
- 100-240 Vac
- Input Voltage Range
- 90-264 Vac
- Nominal Input Frequency
- 50-60 Hz
- Input Frequency Range
- 47-63Hz
- Input Current
- 3.8 A typ. @ 115 Vac, 1.8 A typ. @ 230 Vac
- Input Power (Standby Mode)
- 0.5 W max. @ 230 Vac
- Efficiency at 100% load
- 91.5% typ. @ 230 Vac
- Inrush Current
- 50 A typ. @ 230 Vac
- Case Chassis / Cover
- Aluminum / SGCC
- Cooling System
- Force Cooling
- Operating Temperature
- -40°C to +70°C
- Storage Temperature
- -40°C to +85°C
- Operating Humidity
- 20 to 90% (Non-Condensing)
- Vibration (Non-Operating)
- IEC 60068-2-6, Random: 5 Hz to 500 Hz (2.09G); 20 min per axis for all X, Y, Z direction
- Expected Cap Life Time
- 10 years (230 Vac, 50% load @ 40°C)
- CE
- In conformance with EMC Directive 2014/30/EU and Low Voltage Directive 2014/35/EU
- UKCA
- In conformance with Electromagnetic Compatibility Regulations 2016 and Electrical Equipment (Safety) Regulations 2016
- Harmonic Current Emissions
- IEC/EN/BS EN 61000-3-2, Class A & Class D
- Voltage Fluctuation and Flicker
- IEC/EN/BS EN 61000-3-3
- Line Regulation
- ± 0.5% typ. @ 115 Vac & 230 Vac
- Load Regulation
- ±0.5% typ.
- Start-up Time
- 500 ms typ. @ 115 Vac & 230 Vac
- Hold-up Time
- 16 ms typ. @ 115 Vac & 230 Vac
- Dynamic Response (Overshoot and Undershoot O/P Voltage)
- ± 10% @ 115 & 230 Vac input, 10-100% load (Slew Rate: 2.5 A/µS, 50% duty cycle @ 5 Hz & 10 KHz)
- Vibration (Operating)
- IEC 60068-2-6, Sine Wave: 10 Hz to 500 Hz @19.6 m/s2 (2G); 10 min per cycle, 60 min for each axis (X,Y,Z)
- Shock Test (Non-Operating)
- IEC 60068-2-27, Half Sine Wave: 50G for a duration of 11 ms, 3 shocks for each 3 directions
- Overvoltage
- 39.6 V - 48.6 V SELV Output, Latch Mode
- Overload / Overcurrent
- 110-175% of rated load current, Hiccup Mode, Non-Latching (Auto-Recovery)
- Over Temperature
- Latch Mode
- Short Circuit
- Hiccup Mode, Non-Latching (Auto-recovery when the fault is removed)
- Protection Against Shock
- Class I with Protection Earth connection
- Output Voltage Adjustment Range
- 32.4-39.6 Vdc
- Start-up with Capacitive Loads
- 6,000 µF Max
- Wire
- AWG 18-12
- Operating Altitude
- 0 to 5,000 Meters (0 to 16,400 ft)
- Safety Entry Low Voltage
- SELV
- Immunity
- EN/BS EN 55035, KS C 9835, EN/BS EN 61000-6-2 & Compliance to EN/ BS EN 55014-2 , EN/BS EN 61000-6-1
- DC Input Voltage Range
- 127-375 Vdc
- Indicator
- Green LED (DC OK)
- Shock Test (Operating)
- IEC 60068-2-27, Half Sine Wave: 10G for a duration of 11 ms, 3 shock for each 3 directions.
- Pollution Degree
- 3
- Rise Time
- 30 ms typ. @ 115 Vac & 230 Vac
- Over Voltage Category
- II (Compliance to EN 62477-1 OVC III with 2000 meters altitude)
- Max. Power
- 320.4 W
- Terminal
- M3.5 x 9 Pins (Rated 300 V / 20 A)
Nouveau produit
Aucun avis client pour le moment.