USVI-240024FR
Ficha técnica
- Output Current
- 10A
- Output Voltage
- 24V
- Output Power
- 240W
- Output Current Adjustment Range
- 0.1-10A
- Nominal Input Voltage
- 220-240Vac
- Input Voltage Range
- 198-264Vac
- Nominal Input Frequency
- 50-60 Hz
- Input Frequency Range
- 47-63Hz
- Input Current
- 1.12 typ.
- Efficiency at 100% load
- 92.5% typ. @ 230Vac
- Total Harmonic Distortion
- Meet IEC 61000-3-2 Class C
- Case Chassis / Cover
- Metal sheet
- Cooling System
- Convection
- Operating Temperature
- -40°C to +55°C
- Storage Temperature
- -40°C to +85°C
- Operating Humidity
- 10 to 90% RH (Non-Condensing)
- Storage Humidity
- 5 to 95% RH (Non-Condensing)
- MTBF
- 850,000 hrs. @ta: +45°C (as per Telcordia SR-332 , total failure rate less than 10% )
- Expected Cap Life Time
- 50,000 hrs. at lifetime case temperature
- CE
- In conformance with : Low Voltage Directive 2014/35/EU ; EMC Directive 2014/30/EU ; RoHS Directive 2011/65/EU+ (EU) 2015/863 and Erp Directive 2009/125/EC Implementing measure Commission Regulation (EU) 2019/2020.
- Emission
- Compliance to BS EN/ EN 55015
- Harmonic Current Emissions
- EN 61000-3-2 Class C (230Vac @ 100% load)
- Voltage Fluctuation and Flicker
- EN 61000-3-3
- Line Regulation
- ± 1%
- Load Regulation
- ± 3%
- Overvoltage
- Auto-Recovery when the fault is removed
- Overload / Overcurrent
- Auto-Recovery when the fault is removed
- Over Temperature
- Auto-Recovery when the fault is removed
- Short Circuit
- Auto-Recovery when the fault is removed
- Electrical Safety
- CB scheme: IEC 61347-1, IEC 61347-2-13, IEC 60335-1, IEC 60335-2-89 and Annex BB, IEC 60335-2-24 and Annex CC, SELV Output
- Immunity
- Compliance to BS EN/ EN 61547
Nuevo
No customer reviews for the moment.