Up to 5,000 meters (up to 16,400 feet or 106-54kPa)
Overvoltage
150% max, Latch Mode
Overload / Overcurrent
180% max of rated load current, Hiccup Mode, (Non-Latching, Auto-Recovery)
Over Temperature
Latch Mode
Short Circuit
Hiccup Mode, (Non-Latching, Auto-Recovery)
Degree of Protection
IP22
Protection Against Shock
Class I
MTBF
500K Hours based on Telecordia SR-332 (at 115Vac, Max. load and 25°C Ambient)
CE
In conformance with EMC Directive 2014/30/EU and Low Voltage Directive 2014/35/EU EN 60601-1: 2006 + A1: 2013 + A12: 2014+ A2: 2021 & EN 60601-1-2: 2015 + A1: 2021
UKCA
In conformance with Electrical Equipment (Safety) Regulations 2016 and Electromagnetic Compatibility Regulations 2016, Medical Devices Regulations 2002 (UK MDR 2002)