s1430ros915-carlo gavazzi
s1430ros915-carlo gavazzi
Review:

Your inquiry has been sent successfully

There was an error sending your inquiry.

Check stock

S1430ROS915 Carlo Gavazzi

Amplifier relay for 3 MOF series photocells, Connection 3 barriers, 3 outputs with 2 relays in series
€494.23 (Excl. VAT) €598.02 (inc. VAT)
Tax included
How many units do you want to buy?
Send your query!
S1430ROS915
CARLO GAVAZZI

Novaut is an authorized distributor for CARLO GAVAZZI.
New product
5-7 days
International deliveries
Quantity:
 Calculate Shipping Cost
Free Shipping
to Spain via Correos
Estimated delivery: No estimated delivery specified day(s)
Location: Warehouse 2

S1430ROS915, Photocells Amplifier, Microprocessor Controlled Model S1430 ROS, 3 Inputs/3 Outputs,, S1430ROS915, Microprocessor Controlled Amplifier for 3 sets of photocells, MOFTR, MKFTR, MIFTR or MHFTR models. It has an 11 circular pin connector to facilitate connection. Relay outputs (NA) with 2 relays connected in series. Self-diagnosis for system testing. Protected against reversal of connections or crosstalk of adjacent photocells. Multi-voltage feeds. Adjustable sensitivity for each set of photocells., S1430ROS915, Emitter test (switch 1 up) Placing switch 1 in the top position will flash at the same time all yellow and red LEDs on the front panel of the unit. Once the test is finished (approx. 3 scans), if any wiring failure is detected, such as a polarity reversal or a short circuit, the red LED on the defective emitter will be lit. If no fault is found, only the yellow LED will be lit. If there is a fault, once corrected it, the test will be repeated to make sure that the connections are correct. When the test is over, do not forget to put switch 1 back into normal operating position. Receiver test (switch 2 up) Placing switch 2 in the top position will flash at the same time all yellow and red LEDs on the front panel of the unit. Once the test is finished (approx. 3 scans), if any wiring failure is detected, such as a polarity reversal or a short circuit, the red LED on the defective receiver will be lit. If no fault is found, only the yellow LED will be lit. If there is a fault, once corrected it, the test will be repeated to make sure that the connections are correct. When the test is over, do not forget to put switch 2 back into normal operating position.

S1430ROS915

Specific references

New product

Downloads

No customer reviews for the moment.

Up
Menu
Close
Shopping trolley
Close
Return
Account
Close