rsbs2332a2v22c24hp-carlo gavazzi
rsbs2332a2v22c24hp-carlo gavazzi
Review:

Your inquiry has been sent successfully

There was an error sending your inquiry.

Check stock

copy of RSBS2332A2V22C24HP CARLO GAVAZZI

Single phase starter for scroll compressors, Int. Amp. 32. Ten. line 230 VAC, Auxiliary relay + HP
€332.23 (Excl. VAT) €402.00 (inc. VAT)
Tax included
How many units do you want to buy?
Send your query!
RSBS2332A2V23C24HP
CARLO GAVAZZI

Novaut is an authorized distributor for CARLO GAVAZZI.
New product
5-7 days
International deliveries
Quantity:
 Calculate Shipping Cost
Free Shipping
to Spain via Correos
Estimated delivery: No estimated delivery specified day(s)
Location: Warehouse 2

RSBS2332A2V23C24HP, Motor Controllers Semiconductor controller for AC motors model RSBS23.. A2V.2C24.., RSBS2332A2V23C24HP, This motor controller, designed for use with single-phase scroll compressors can limit starting currents to 40ACArms with the RSBS2332A2V23C24HP. and 45ACArms with RSBS2332A2V23C24HP. A soft start is achieved in an interval2 of 600ms when applying the control signal. At the end of the soft start function, the semiconductors are bridged by electromechanical relays. The rated capacity of the controller is a maximum of 12 starts per hour 3. The delay between starts and/or from stop to start is indicated by the orange LED. The green LED indicates the application of the supply voltage, remaining on continuously. The alarm indication is made by a red LED that indicates the type of alarm by a sequence of flashes. This controller does not include protections against short circuits or overload so they must be installed externally and with specific values. Starter capacitors are built-in. All RSBS versions are optionally supplied with an auxiliary alarm relay (option V22). Note: Power and bypass relays may be in an undefined state due to transport. In case the relays are in the ON state, a direct in-line start of the compressor will occur – even without the control signal. To avoid direct online booting, the user should activate it without any load connected for ≥ 3 seconds., RSBS2332A2V23C24HP, RSBS.. V.2C24HP should attempt to gently start the compressor by limiting the starting currents to 45ACArms. Depending on the load requirements, the current limit will gradually increase to a maximum of 80ACArms, after which RSBS will go into bypass mode. If the ramp is not performed after a maximum of 1 second, the incomplete ramp alarm (5 flashes of the red LED) will be triggered and RSBS will enter recovery mode for 5 minutes. If on the second consecutive attempt, RSBS generates the incomplete ramp alarm again, user intervention will be necessary to reset the power in the RSBS, as it may be an indicator of a real blocked rotor condition. For RSBS2332A2V23C24HP models, when K1 is opened, the red LED will remain lit until the minimum time between starts and/or the minimum time between stops/starts has elapsed.

RSBS2332A2V23C24HP

Specific references

New product

No customer reviews for the moment.

Up
Menu
Close
Shopping trolley
Close
Return
Account
Close