Related products
The PCE Instruments durometer measures according to the Leeb rebound method. This is a dynamic test method that uses a standard hammer body, usually a metal ball, to impact a surface with a defined energy. As a consequence, a plastic deformation is generated on the surface where the metal ball bounces. This deformation results in a loss of energy that is proportional to the hardness of the test piece, and which is determined through the relationship between the impact velocity and the rebound velocity. The hardness tester is shipped with a type D firing pin, but optionally you can connect other firing pin sensors for special applications (DC, DL, C, D+15, E, G). You can also store the values on a USB stick, which expands the flexibility of this device. The hardness tester is easy to use thanks to its intuitive menu using symbols and an easy-to-read OLED display and an ergonomic housing.
- Measures common hardness units
- External firing pin sensor with 1.5 m cable
- Large measuring range
- High accuracy
- Data logging on USB stick
- Other firing pins optionally available
- Ability to measure at various angles
- Color display
Hardness tester PCE-2000N | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Technical Specifications | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Rank | 170 ... 960 HLD 17,9 ... 69.5 HRC 19 ... 683 HB 80 ... 1042 HV 30,6 ... 102.6 HS 59,1 ... 88 HRA 13,5 ... 101.7 HRB | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Hammer sensor included (optional firing pin sensors) | D (DC, D+15, C, G, DL) | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Hammer Sensor Cable Length | Approx. 1.5 m | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Precision | ±0.5% (@800 HLD) | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Reproducibility | 0.8% (@800 HLD) | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Hardness Units | HL (Leeb) HV (Vickers) HB (Brinell) HS (Shore) HRA (Rockwell A) HRB (Rockwell B) HRC (Rockwell C) | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Materials to be measured | Steel Cast steel Alloy steel Stainless steel Grey Fade Spheroidal cast Cast Aluminum Alloy Cu-Zinc (Brass) Copper-tin alloy Copper | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Screen | OLED, 128 x 64 pixels | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Memory | 600 average values across 6 data sets | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Data Output | USB Flash Drive | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Feeding | 3 x 1.5V batteries, type AAA | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Automatic shut-off | After 12 minutes of inactivity | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Operating Conditions | +10 ... +50 °C / 20 ... 90% H.r. | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Storage conditions | -30 to +60 °C | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Dimensions | 160 x 80 x 40 mm | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Weight | Battery-powered device: approx. 300 g Hammer sensor: approx. 75 g | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
What's in the Shipment 1 x Hardness Tester PCE-2000N 1 x Calibration Block 1 x Type D Hardness Tester 1 x Carrying case 1 x Cleaning Brush 1 x Instruction Manual 3 x 1.5V batteries, type AAA 1 x Replacement Support Ring 1 x 2GB USB Flash Drive 1 x Factory Calibration Certificate |
No customer reviews for the moment.