drm-24v960w3pn-delta psu
drm-24v960w3pn-delta psu
Review:

Your inquiry has been sent successfully

There was an error sending your inquiry.

Captcha validation failed.

Check stock

DRM-24V960W3PN DELTA

DRM-24V960W3PN DELTA
€522.77 (Excl. VAT) €632.55 (inc. VAT)
Tax included
Novaut is an authorized distributor for DELTA.
New product
New: Product directly from the manufacturer in original sealed packaging. Manufacturer warranty.

New surplus: Brand new equipment never used. Comes from excess materials or leftover from a project. May come in sealed original box, opened original box, or without original box, but equipment is completely new. NOVAUT warranty.

Refurbished: Products given a second life. High-quality products with worn components replaced, boards cleaned and treated. Fully tested to ensure proper functioning, remanufactured products. NOVAUT warranty.

Used: Products that have been used, not tested. NOVAUT warranty in case they do not function correctly.
/ Warranty: 3 years
5-7 days
International deliveries
How many units do you want to buy?
Send your query!
DRM-24V960W3PN
DELTA
Power Supplies DELTA DELTA
Quantity Price (Exc. VAT) Price (inc. VAT)
1 - 4 €522.77 €632.55
5 - 9 €502.45 €607.96
10 - 14 €473.21 €572.58
15 - 19 €436.55 €528.23
> 19 €390.18 €472.12
Novaut is an authorized distributor for DELTA.
New product
New: Product directly from the manufacturer in original sealed packaging. Manufacturer warranty.

New surplus: Brand new equipment never used. Comes from excess materials or leftover from a project. May come in sealed original box, opened original box, or without original box, but equipment is completely new. NOVAUT warranty.

Refurbished: Products given a second life. High-quality products with worn components replaced, boards cleaned and treated. Fully tested to ensure proper functioning, remanufactured products. NOVAUT warranty.

Used: Products that have been used, not tested. NOVAUT warranty in case they do not function correctly.
/ Warranty: 3 years
5-7 days
International deliveries
Quantity:
 Calculate Shipping Cost
Free Shipping
to Spain via Correos
Estimated delivery: No estimated delivery specified day(s)
Location: Warehouse 118

Related products

DRM-24V960W3PN DELTA
DELTA
DRM-24V960W3PN

Sheet

Output Current
40A
Output Voltage
24V
Output Voltage Range
24-28Vdc
Output Power
960W
Nominal Input Voltage
3 x 400-500Vac
Input Voltage Range
3 x 320-575Vac (3-Phase) or 2 x 380-575Vac (2-Phase)
Nominal Input Frequency
50-60Hz
Input Frequency Range
47-63Hz
Input Current
1.53A @ 24V, 40A
Efficiency at 100% load
95.75% @ 24V, 40A
Inrush Current
14.2A
Power Factor at 100% load
0.95 @ 24V, 40A
Case Chassis / Cover
Aluminium
Cooling System
Convection
Input Terminal
4 Pins (Rated 600V/35A)
Output Terminal
4 Pins (Rated 300V/65A)
Operating Temperature
-25°C to +70°C (Cold start -40°C)
Storage Temperature
-40°C to +85°C
Operating Humidity
5 to 95% RH (Non-Condensing)
Vibration (Non-Operating)
IEC 60068-2-6, Sine Wave: 10-500Hz; 3G peak; displacement of 0.35mm; 60 min per axis for all X, Y, Z directions
Degree of Protection
IP20
Expected Cap Life Time
368,800 hrs. @ I/P: 3 x 400Vac, O/P: 24V, 20A, Ta: 25°C
CE
In conformance with EMC Directive 2014/30/EU and Low Voltage Directive 2014/35/EU
UKCA
In conformance with Electrical Equipment (Safety) Regulations 2016 No. 1011 and The Electromagnetic Compatibility Regulations 2016 No. 1091
Harmonic Current Emissions
IEC/EN/BS EN 61000-3-2, Class A
Voltage Fluctuation and Flicker
IEC/EN/BS EN 61000-3-3
Line Regulation
10mV (@ 3 x 320-575Vac input, 100% load)
Load Regulation
80mV (@ 3 x 320-575Vac input, 0-100% load)
Start-up Time
1,000ms @ 24V, 40A
Hold-up Time
50.4ms @ 24V, 20A
Dynamic Response (Overshoot and Undershoot O/P Voltage)
± 5% @ 1.5-100% load
Shock Test (Non-Operating)
IEC 60068-2-27, Half Sine Wave: 30G for a duration of 18ms; 3 times per direction, 6 times in total
Overload / Overcurrent
150-200% of rated load current, Constant current, Hiccup Mode (Auto-Recovery)
Short Circuit
Hiccup Mode, Non-Latching (Auto-recovery when the fault is removed)
Protection Against Shock
Class I with Primary Earth connection
Output Voltage Adjustment Range
24-28Vdc
Start-up with Capacitive Loads
40,000µF
Safety Entry Low Voltage
SELV (IEC 60950-1)
Immunity
Generic Standards: EN/BS EN 55024, EN/BS EN 55035, EN 61000-6-2
PARD
100mVpp Max.
DC Input Voltage Range
450-800Vdc
Pollution Degree
2
Industrial Control Equipment
UL/cUL listed: UL 508 and CSA C22.2 No. 107.1-01 (File No. E315355)
Component Power Supply for General Use
EN/BS EN 61204-3
Rise Time
65ms
Signal Terminal
5 Pins (Rated 300V/12A)
Power Boost Recovery Time
17 seconds Typ.
Mounting Rail
Standard TS35 DIN Rail in accordance with EN 60715
Bump Test (Operating)
IEC 60068-2-29, Half Sine Wave: 10G for a duration of 11ms, 1,000 times per direction, 6,000 times in total
Electrical Equipments of Machines
EN/BS EN 60204-1 (over voltage category III)
Electrical Equipment for Use in Electrical Power Installations
IEC/EN/BS EN 62477-1 / IEC 62103