EUCO-600200GDA
Sheet
- Output Current
- 2A
- Output Voltage
- 200-550V
- Output Power
- 600W
- Nominal Input Voltage
- 220-400Vac
- Input Voltage Range
- 198-440Vac
- Nominal Input Frequency
- 50-60Hz
- Input Frequency Range
- 47-63Hz
- Case Chassis / Cover
- Aluminum case, color: anodized (Nature)
- Operating Temperature
- -40 ~+60°C
- Storage Temperature
- -40°C to +85°C
- Operating Humidity
- 10% to 90% RH (Non-Condensing)
- Vibration (Non-Operating)
- IEC 60068-2-6, Random: 5 Hz to 10 Hz (1G); 30 min per axis for all X, Y, Z direction
- Degree of Protection
- IP66
- CE
- CE Declaration of Conformity
- UKCA
- BS EN 61347-2-13: 2014+A1:2017
- Harmonic Current Emissions
- EN61000-3-2
- Cooling System
- Natural Convection
- Expected Cap Life Time
- 50,000 hours applicable for 220 Vac to 400 Vac(50/60 Hz) @100% of load, @ Ta 45°C
- Voltage Fluctuation and Flicker
- EN61000-3-3
- Voltage Dips
- EN 61000-4-11
- Input Terminal
- Wieland RST 20I3F S2 M01VH GN0 With the definition of L1, L2, PE
- Output Terminal
- Amphenol CC-03PMFS-QC801P With the definition of NTC, V+, V-
- ESD Immunity
- EN 61000-4-2
- EFT
- EN 61000-4-4
- Magnetic Field
- EN 61000-4-3
- Storage Humidity
- 10% to 90% RH (Non-Condensing)
- Output Voltage Range
- 200-550Vdc
- Max Output Voltage
- 600Vdc
- Output Current Adjustment Range
- 0.7-2A
New