MDS-300ADB48 AB
Sheet
- Output Current
- 6.25A
- Output Voltage
- 48V
- Output Power
- 300W
- Line Regulation
- ±0.5%
- Load Regulation
- ±1%
- Start-up Time
- 2000ms @ 115Vac
- Dynamic Response (Overshoot and Undershoot O/P Voltage)
- ± 5% @ with 50-100% load change
- Nominal Input Voltage
- 100-240Vac
- Input Voltage Range
- 90-264Vac
- Nominal Input Frequency
- 50-60Hz
- Input Frequency Range
- 47-63Hz
- Input Current
- 4A
- Case Chassis / Cover
- Enclosed cover
- Storage Temperature
- -40°C to +85°C
- Operating Humidity
- 5-95% RH (Non-Condensing)
- Shock Test (Non-Operating)
- 50G, 11ms, 3 shocks for each direction
- Operating Altitude
- 5,000 meters (16,400 feet or 50kPa)
- Over Temperature
- Latch Mode for Main output
- Short Circuit
- Hiccup Mode, (Non-Latching, Auto-Recovery)
- MTBF
- 800 Khrs based on Telecordia SR-332
- Emission
- EN55011/EN55032,FCC Title 47:Class B
- Harmonic Current Emissions
- IEC61000-3-2 Class D limit
- PARD
- 1% pk-pk Vrated@ Full load
- Rise Time
- 100ms
- Power Factor at 100% load
- 0.95 @ 115V/50Hz, 230V/50Hz, full load
- Power De-rating
- Linear power derate from 100% load at 50°C, to 50% load at 70°C
- Voltage Fluctuation and Flicker
- IEC61000-3-3
- Inrush Current
- 40A @ 230Vac, cold start
- Vibration (Operating)
- 5-500Hz, 2Grms, 15 minute for each three axis
New product