Dynamic Response (Overshoot and Undershoot O/P Voltage)
± 5% @ 50-100% load
Nominal Input Voltage
100-240Vac
Input Voltage Range
90-264Vac
Nominal Input Frequency
50-60Hz
Input Frequency Range
47-63Hz
Input Current
5.5A
Case Chassis / Cover
NA
Operating Temperature
-10°C to +70°C,
Storage Temperature
-40°C to +85°C
Operating Humidity
5-95% RH (Non-Condensing)
Shock Test (Non-Operating)
50G, 11ms, 3 shocks for each direction
Overvoltage
135% of rated voltage, Latch Mode
Over Temperature
Latch Mode
MTBF
500 kHrs based on Telecordia SR-332 at 100 Vac, 400 W, ambient 25 °C
UKCA
In conformance with Electrical Equipment (Safety) Regulations 2016 and Electromagnetic Compatibility Regulations 2016, Medical Devices Regulations 2002 (UK MDR 2002)
Emission
EN/BS EN 55011 & compliant with EN/BS EN 55032, FCC Title 47:Class B
Harmonic Current Emissions
IEC 61000-3-2 Class D limit
Power De-rating
power linearly de-rate from 50°C to 50% rated up to 70°C with 12 CFM forced air