EUCI-022105GLB
Sheet
- Output Current
- 0.2-1.05A
- Output Voltage
- 8-48V
- Output Power
- 22W
- Line Regulation
- ± 3% (@ 220-240Vac)
- Load Regulation
- ± 5% (@ Min-Max output voltage)
- Start-up Time
- 520~1000ms max. (@ 220-240Vac)
- Nominal Input Voltage
- 220-240Vac
- Input Voltage Range
- 198-264Vac
- Nominal Input Frequency
- 50-60Hz
- Input Frequency Range
- 47-63Hz
- Input Current
- 0.12A @ 230Vac
- Case Chassis / Cover
- Plastic
- Operating Temperature
- -40°C to +55°C
- Storage Temperature
- -40°C to +85°C
- Operating Humidity
- 10 to 90% RH (Non-Condensing)
- Overvoltage
- 90Vrms, Luminaries will work normally when the fault is removed
- Overload / Overcurrent
- Reduce output current. Auto-Recovery when the fault is removed
- Over Temperature
- Reduce output current. Auto-Recovery when the fault is removed
- Short Circuit
- Auto-Recovery when the fault is removed
- Degree of Protection
- IP20
- MTBF
- 50,000 hours @ lifetime case temperature
- CE
- In conformance with EMC Directive and Low Voltage Directive
- Cooling System
- Convection
- Immunity
- Compliance to EN 61547
- Inrush Current
- 20A/250uS @ 230Vac
- Storage Humidity
- 5 to 95% RH (Non-Condensing)
- Output Voltage Range
- 8-48Vdc
- Max Output Voltage
- 90Vdc
- Material and Parts
- RoHS Directive 2011/65/EU Compliant
New
No customer reviews for the moment.