DPC01DM69 Carlo Gavazzi
Review:

Your inquiry has been sent successfully

There was an error sending your inquiry.

Captcha validation failed.

Check stock

DPC01DM69 Carlo Gavazzi

Three-phase max and min control relay voltage, sequence, loss and phase asymmetry
€268.72 (Excl. VAT) €325.15 (inc. VAT)
Tax included
Novaut is an authorized distributor for CARLO GAVAZZI.
New product
New: Product directly from the manufacturer in original sealed packaging. Manufacturer warranty.

New surplus: Brand new equipment never used. Comes from excess materials or leftover from a project. May come in sealed original box, opened original box, or without original box, but equipment is completely new. NOVAUT warranty.

Refurbished: Products given a second life. High-quality products with worn components replaced, boards cleaned and treated. Fully tested to ensure proper functioning, remanufactured products. NOVAUT warranty.

Used: Products that have been used, not tested. NOVAUT warranty in case they do not function correctly.
/ Warranty: 1 year
5-7 days
0.22 Kg
International deliveries
How many units do you want to buy?
Send your query!
DPC01DM69
8030956000245
CARLO GAVAZZI

Novaut is an authorized distributor for CARLO GAVAZZI.
New product
New: Product directly from the manufacturer in original sealed packaging. Manufacturer warranty.

New surplus: Brand new equipment never used. Comes from excess materials or leftover from a project. May come in sealed original box, opened original box, or without original box, but equipment is completely new. NOVAUT warranty.

Refurbished: Products given a second life. High-quality products with worn components replaced, boards cleaned and treated. Fully tested to ensure proper functioning, remanufactured products. NOVAUT warranty.

Used: Products that have been used, not tested. NOVAUT warranty in case they do not function correctly.
/ Warranty: 1 year
5-7 days
0.22 Kg
International deliveries
Quantity:
 Calculate Shipping Cost
Free Shipping
to Spain via Correos
Estimated delivery: No estimated delivery specified day(s)
Location: Warehouse 2

DPC01DM69, Control relays and Protection Control Multifunction Three-phase, Three-phase with Neutral, TRMS Models DPC01, PPC01, DPC01DM69, Three-phase or three-phase line voltage control relay with neutral for phase sequence control, phase breakage, asymmetry, tolerance, max. and min. voltage (with independent adjustments), with delay function. Measurement scale from 100 to 690 WL available from three multi-voltage relays., DPC01DM69, Definition of asymmetry. Asymmetry is an indicator of the quality of the network and is defined as the absolute value of the maximum deviation between the voltages of the network, divided by the nominal voltage of the three-phase system. The definition changes according to the voltage reference: 1) If phase-phase voltages are measured: max |∆VPH-PH| V∆NOM 2) If phase-neutral voltages are measured: max |∆VPH-N| V NOM Definition of tolerance. Tolerance is another indication of the quality of the network and is defined as the absolute value of the maximum deviation of the mains voltages from the nominal voltage, divided by the nominal voltage of the three-phase system. The definition changes according to the voltage reference: 1) If phase-phase voltages are measured: max | V∆NOM - HPV-PH| V∆NOM 2) If phase-neutral voltages are measured: max | V NOM - HPV-N| V NOM Connected to the 3 phases (and neutral) the DPC01 and PPC01 relays connect when all 3 phases are present at the same time and the phase sequence is correct. It is possible to decide whether to control the max level and min. voltage level of each phase or its asymmetry and tolerance. In any case, if the phase-neutral measurement is selected, both phase-phase voltages and phase-neutral stresses shall be controlled. Voltage level control: If one or more phase-phase or phase-neutral voltages exceed the selected max level or fall below the selected min level, the red LED starts flashing at 2 Hz and the corresponding relay output disconnects after the set delay period. Asymmetry and tolerance control: if one of the phases exceeds the adjusted level, the red LED starts flashing at 2 Hz and the corresponding output relay fires after the adjusted delay period. NOTE: If the phase sequence is correct or a phase loss occurs, the output relay disconnects immediately after the 200 ms delay period. The fault will be indicated by the red LED flashing at 5 Hz during the alarm condition Example 1 (network control - max. and min. phase voltage level) The relay controls the max and min phase-phase voltage level, phase breakage and the correct phase sequence of phases. Example 2 (Control of starting loads and operation of motors - asymmetry and phase-neutral tolerance) The DPC01 and PPC01 relays ensure correct operating conditions. They control the voltage level, the sequence of phases (the correct direction of rotation of the motor) and the asymmetry. The most frequent failures are the breakage of fuses and the incorrect level of tension. In the case of broken fuses, the motor regenerates a voltage in the interrupted phase. These relays detect the fault and react to any excessive imbalance between the phases.

DPC01DM69

Specific references

New product

Downloads