nlg13d724sa-carlo gavazzi
nlg13d724sa-carlo gavazzi
Reseña:

Your inquiry has been sent successfully

There was an error sending your inquiry.

Consulta disponibilidad

NLG13D724SA Carlo Gavazzi

Módulo de seguridad - Barrera de seguridad. Terminales a tornillo fijo
331,37 € (excl. IVA) 400,96 € (inc. IVA)
Impuestos incluidos
¿Cuántas unidades te gustaría comprar?
¡Envía tu consulta!
NLG13D724SA
CARLO GAVAZZI

Novaut es distribuidor autorizado de CARLO GAVAZZI.
Nuevo
5-7 días
Entregas internacionales / International deliveries
Cantidad:
 Calcular gastos de envío
Envío gratis
hasta España vía Correos
Entrega estimada: No se especificó entrega estimada días hábiles
Ubicación: Almacén 2

NLG13D724SA, Safety Modules Light curtains Types NLG02D, NLG13D, NLG13D724SA, NLG02D and NLG13D are safety modules designed to monitor sefety light curtains with PNP or relay outputs according to 98/37/EC Machinery Directive. This family of safety modules in Safety Category 4, Performance Level e, includes fixed screw and detachable screw as well as automatic/manual or monitored manual restart versions., NLG13D724SA, The safety modules NLG02D and NLG13D monitor ElectroSensitive Equipments (ESPE) with PNP or relay outputs according to 98/37/EC Machinery Directive. If the safety system (NLG+ESPE) is correctly supplied, the input terminals of the module are activated (light beams not interrupted) and there aren’t fault conditions, the module is enabled to close the safety outputs and the external contactors can be energized. When the input terminals are not activated (light beams interrupted) the module is not enabled to close the safety outputs and the external contactors can not be energized. Automatic START Provided that the terminals X1 and X2 (NLG02...A) or S33 and S34 (NLG13...A) are connected, the safety outputs close and the auxiliary output opens (NLG13...A) as soon as both the module inputs are activated. The relevant CH1 and CH2 LED turn on. Deactivating even one module input forces immediately the safety outputs to open and the auxiliary output (NLG13...A) to close. A new operating cycle is possible only after deactivating both input contacts and then operating them again. Manual START Provided that both the module inputs are activated, the safety outputs close and the auxiliary output opens (NLG13...A) as soon as the NO START pushbutton is pushed connecting X1 and X2 (NLG02...A) or S33 and S34 (NLG13...A). A new operating cycle is possible only after deactivating both the module inputs, activating them again and pushing the START button. Monitored manual START The monitored manual START versions (NLG...C) work as described in the previous paragraph (Manual START) except for a minimum delay of 500 ms from the activated status of the module inputs to the pushing of the START button. If the inputs of the module are closed with the START switch already closed, the safety outputs don’t close and the auxiliary doesn’t open (NLG13...C): it is necessary to release the START button and deactivate the module inputs before starting a new cycle, then operate the inputs of the module and finally, after at least 500 ms, operate the START button. So if the NO START button gets welded, the outputs don’t close anymore.

NLG13D724SA

Referencias específicas

Nuevo

Descargas

No customer reviews for the moment.

Arriba
Menú
Cerrar
Carrito
Cerrar
Volver
Cuenta
Cerrar